Datalogic Scanning 9500 Scanner User Manual


 
F-2 Magellan
®
9500
Datalogic Handheld Data Format Requirements
The following sections describe label transmission formats that are typi-
cally observed in factory configurations of Datalogic handheld scanners.
RSS-14
Prefix must be ASCII characters ‘R4’
Check character must be included in label
Application identifier “01” must follow the prefix and preceed the
base label
Label length excluding prefix characters must be 16 characters.
Example: ‘R40101044123456789’
RSS Expanded
Prefix must be ASCII characters ‘R4’
Check character must be included in label
UPC-A
Number system must be included in label data.
Check digit must be included in label data and is assumed to be cor-
rect.
Prefix must be an ASCII character 'A' - total length including prefix
must be 13.
Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be cor-
rect.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including prefix
must be 15.
Example: 'A06099201118712'.