C-BOX 200 DATALOGIC
8 - Installation
2.4.2 System Wiring
The connection and wiring procedure for C-BOX 200 is described as follows:
1) Open the C-BOX 200 as described in paragraph 2.2.
2) Verify that the C-BOX 200 power switch is off (see Figure 2.6).
3) Unscrew the compression connectors and pass all the system
cables through them into the C-BOX 200 housing.
4) To connect the power and input/output signals:
• Prepare the individual wires of the system cables by stripping the
insulation back approximately 1 cm.
• Using a device such as a screwdriver, push down on the lever
directly next to the clamp (see Figure 2.8).
• Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
Figure 2.8 - System cable connections
The wiring used can be solid or stranded but must meet the following
specifications.
All positions: 24 - 16 AWG 0.2 - 1.5 mm²