DS4600A QUICK GUIDE
6
Reading Diagrams:
DS4600A-210X (Long Range)
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 15°
Tilt angle = 0°
*Code Resolution:
Standard - for 0.50 mm (20 mils) codes
and greater
*Code Reading Condition:
Standard
* Parameter selectable in WinHost.
4
-4
12
-12
-16
(in)
04 2012
(in)
816
0
100 200 300 400 500 600 700 800 900 1000
(mm)
400
300
200
100
0
-100
-200
-300
-400
(mm)
24 28 32 36 40
16
8
-8
0.50 mm
(20 mils)
0.60 mm
(24 mils)
0.80 mm
(31 mils)
1.00 mm
(40 mils)
DS4600A-200X (Medium Range)
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 15°
Tilt angle = 0°
*Code Resolution:
High - for 0.30 mm (12 mils) codes and
smaller
Standard - for 0.50 mm (20 mils) codes
and greater
*Code Reading Condition:
Standard
* Parameter selectable in WinHost.
4
2
0
-2
10
8
6
-4
-6
(in)
02 6412
(in)
8 10 14 16 18
0
50
100
150 200 250 300 350 400 450 500 550
(mm)
250
200
150
100
50
0
-50
-100
-150
-200
-250
(mm)
20 22
0.25 mm
(10 mils)
0.30 mm
(12 mils)
0.50 mm
(20 mils)
-8
-10