Datalogic Scanning DS8100A-3002 Scanner User Manual


 
DS8100A-3002 QUICK GUIDE
9
Reading Diagrams:
Note: (0,0) is the center of the laser beam output window.
DS8100A-3002 – 0.50 mm/20 mils
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
“Pitch“ angle = 0°
“Skew“ angle = 10°
“Tilt“ angle = 0°
(in)
015 32
(in)
24 40
0
40
60
(cm)
20
10
-10
0
(cm)
80
100 120 140
48 56
160
64
40
50
60
30
-40
-30
-20
-60
-50
12
8
0
4
20
24
16
-12
-8
-4
-20
-16
-24
Safety Precautions:
Figure A
Laser Safety Label
1
Warning and Device Class Label
2
Identification Label
3
The scanner is classified as a Class 2 laser product according to EN60825-1 regulations and as a Class II laser
product according to CDRH regulations.
Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to
hazardous laser light.
There is a safety device, which allows the laser to be switched on only if the motor is rotating above the threshold
for its correct scanning speed.
1
2
3