Datalogic Scanning GM4100 Barcode Reader User Manual


 
LED and Beeper Indications
38 Gryphon™ I GM4100
Reader
Disabled
The reader has
been disabled by
the host.
The LED blinks
continuously
N/A
Green Spot is on
continuously
While in Stand
Mode or Trigger
Stand Mode the
green spot shall
be on while in
stand watch
state.
N/A N/A
Green Spot
a
flashes momen-
tarily
Upon successful
read of a label,
the software shall
turn the green
spot on for the
time specified by
the configured
value.
N/A N/A
Programming Mode - The following indications ONLY occur when the reader is
in Programming Mode.
Label Program-
ming Mode
Entry
A valid program-
ming label has
been scanned.
LED blinks con-
tinuously
Reader sounds
four low fre-
quency beeps.
Label Program-
ming Mode
Rejection of
Label
A label has been
rejected.
N/A
Reader sounds
three times at
lowest fre-
quency and cur-
rent volume.
Label Program-
ming Mode
Acceptance of
Partial Label
In cases where
multiple labels
must be scanned
to program one
feature, this indi-
cation acknowl-
edges each
portion as it is
successfully
scanned.
N/A
Reader sounds
one short beep at
highest fre-
quency and cur-
rent volume.
INDICATION DESCRIPTION LED BEEPER