TECHNICAL FEATURES
6
6 TECHNICAL FEATURES
6.1 GRYPHON DX30
Electrical Features
Power Supply
5 Vdc ± 5%
Consumption:
Gryphon D130 Gryphon D230
Maximum
Operating
Sleep mode/USB Suspend
270 mA@ 5 Vdc
165 mA@ 5 Vdc
<500 µA@ 5 Vdc
270 mA@ 5 Vdc
210 mA@ 5 Vdc
4 mA@ 5 Vdc
Max. Scan Rate 270 scans/sec
Reading Indicators LED, Good Read Spot, Beeper
Optical Features
Sensor CCD solid state (3648 pixels)
Illuminator LED array
Wavelength 630 ~ 670 nm
Max. LED Output Power 0.33 mW
LED Safety Class Class 1 EN 60825-1
Reading Field see reading diagram
Max. Resolution
Gryphon Dx30-Std Gryphon D130-LR
0.076 mm (3 mils) 0.11 mm (4.3 mils)
PCS (Datalogic Test Chart) min. 15%
Environmental Features
Working Temperature
0 °C to + 55 °C / 32° to +131 °F
Storage Temperature
-20 °C to + 70 °C / -4° to +158 °F
Humidity 90% non condensing
Drop Resistance
IEC 68-2-32 Test ED
1.8 m (5 ft. 11 in.)
Protection Class IP30
Mechanical Features
Weight (without cable) about 210 g. (7.4 oz.)
Cable Length 2 m. (6 ft. 6 in.)