4.0.3 Quick Test Mode: Print Test Labels
;
Note: The Quick Test Mode functions are disabled while processing data
from communications interfaces until the Host Timeout value expires.
n
The DOWN ARROW Key scrolls to the previous
test function.
o
The UP ARROW Key scrolls to the next test
function.
p
The ENTER Key will change the selected test
label quantity of 2, 100, 1000, or 9999 (except the
‘Configuration Label’, quantity of one). Holding
down the key scrolls quantities.
q
The ESCAPE Key will exit the Quick Test Mode
without printing.
r
The TEST Key will print the selected test label at
the selected quantity. During test label printing,
this key also functions as a cancel key (the printer
will prompt you for confirmation before
cancellation occurs).
You can program a time delay between the printing of test labels using
the ‘Print Test Rate’ feature; see Section 4.1.7.