Dell 2850 Laptop User Manual


 
Information Update 7
E0000 OVRFLW CHECK LOG LCD overflow message.
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
Check the SEL for details
on the events.
E0119 TEMP AMBIENT
TEMP BMC
Ambient system temperature is
out of acceptable range.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
E0119 TEMP RISER Riser card is out of acceptable
temperature range.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
E0212 VOLT PG n System power supply is out of
acceptable voltage range; faulty
or improperly installed power
supply.
See "Troubleshooting Redundant
Power Supplies" in your
Installation and Troubleshooting
Guide.
E0212 VOLT BATT ROMB Faulty RAID battery. Replace the RAID battery.
See "Activating the Optional
Integrated RAID Controller"
in your Installation and
Troubleshooting Guide.
E0212 VOLT BATT CMOS Faulty system battery. Replace the system battery.
See "System Battery" in your
Installation and Troubleshooting
Guide.
E0212 VOLT RISER 5V
VOLT RISER
Riser card voltage is out of
acceptable range; faulty or
improperly installed power
supply; faulty system board.
Reinstall the expansion-card cage.
See "Installing the Expansion-
Card Cage" in your Installation
and Troubleshooting Guide. If the
problem persists, see "Getting
Help" in your Installation and
Troubleshooting Guide.
E0412 RPM FAN n
FAN REDUNDANCY
LOST
Specified cooling fan is faulty,
improperly installed, or missing.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
Table 1-4. LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes Corrective Actions