Dell FE200/FL200 Computer Accessories User Manual


 
2-2 Installation and Troubleshooting Guide
2. Cable the system hardware for clustering.
If you are using Dell PowerVault Fibre Channel switches, see the Dell PowerEdge
Cluster F-Series SAN Guide for more information.
3. If you are using hardware-based RAID for the internal SCSI hard-disk drives, con-
figure them using the controllers basic input/output system (BIOS) utility.
4. Perform the low-level configuration of the HBAs.
5. Install and configure the Windows NT 4.0 Server, Enterprise Edition operating
system on each node.
6. Configure the public and private NIC interconnects in each node, and place the
interconnects on separate Internet protocol (IP) subnetworks using static IP
addresses.
NOTES: Publicrefers to the NIC used for client connections. Privaterefers to
the dedicated cluster interconnect.
If you are using Giganet cluster local area network (cLAN) Host Adapters or a
Giganet cLAN Cluster Switch, see Using Giganet for Cluster Interconnect (Pow-
erEdge Cluster FL100/FL200)in Chapter 4 for more information.
7. Install the device driver for the integrated video controller.
8. Install Windows NT Service Pack 6a or later.
NOTE: See the Dell PowerEdge Cluster FE100/FL100 and FE200/FL200 Platform
Guide for more information on the latest supported service pack.
9. Install the miniport driver for the Fibre Channel HBAs in each node.
10. Install the QLogic Fibre Channel Configuration software.
11. Install the storage management software and failover driver that is appropriate for
your storage system.
For the PowerEdge Cluster FE100/FL100, perform the following steps:
a. Install Dell OpenManage Application Transparent Failover (ATF) software on
each node and reboot.
b. Install Dell OpenManage Managed Node (Data Agent) on each node.
c. Install Dell OpenManage Data Supervisor or Dell OpenManage Data Admin-
istrator on node A.
For the PowerEdge Cluster FE200/FL200, perform the following steps:
a. Install QLDirect on each node and reboot.
b. Set the failover path in the QLogic Fibre Channel Configuration software on
each node.
c. Reboot each node.