Dell G2410T Computer Monitor User Manual


 
Environmental Characteristics
Power Management Modes
IfyouhaveVESA'sDPM™compliancedisplaycardorsoftwareinstalledinyourPC,themonitorcanautomaticallyreduceitspowerconsumptionwhennotin
use. This is referred to as Power Save Mode*. If the computer detects input from keyboard, mouse, or other input devices, the monitor automatically resumes
functioning. The following table shows the power consumption and signaling of this automatic power saving feature:
^^Based on measurement of standby power consumption using VGA input
The OSD will only function in the normal operation mode. When the menu or plus buttons are pressed in Active-off mode, one of the following messages will be
displayed:
Analog Input In Power Save Mode. Press Computer Power Button or Any Key on Keyboard or Move Mouse
OR
Digital Input In Power Save Mode. Press Computer Power Button or Any Key on Keyboard or Move Mouse
Activate the computer and the monitor to gain access to the OSD.
* Zero power consumption in OFF mode can only be achieved by disconnecting the main cable from the monitor.
Pin Assignments
VGA Connector
Weight without stand assembly
(For wall mount or VESA mount considerations -
no cables)
8.86 lb (4.02 kg)
Weight of stand assembly
3.63 lb (1.65 kg)
Model
G2410H
Temperature
Operating
5°to35°C(41°to95°F)
Non-operating
Storage: -20°to60°C(-4°to140°F)
Shipping: -20°to60°C(-4°to140°F)
Humidity
Operating
10% to 80% (non-condensing)
Non-operating
Storage: 5% to 90% (non-condensing)
Shipping: 5% to 90% (non-condensing)
Altitude
Operating
3,657.6 m (12,000 ft) max
Non-operating
12,192 m (40,000 ft) max
Thermal dissipation
98.977 BTU/hour (maximum)
68.26 BTU/hour (typical)
VESA Modes
Horizontal Sync
Vertical Sync
Video
Power Indicator
Power Consumption
Normal operation
Active
Active
Active
Blue
20 W (typical)/29 W (maximum)
Active-off mode
Inactive
Inactive
Blanked
Amber (breathing)
0.15 W^^
Switch off
-
-
-
Off
Less than 0.15 W
NOTE: This monitor is ENERGY STAR®-compliant as well as TCO '03 power management compatible.