Switch Mode Power Supply DRP024V060W1BA
3/13 Rev: 00,
1/10/2011
General Data
Isolation voltage:
Input / output type test/routine test
Input / PE type test/routine test
output / PE type test/routine test
4 KVAC / 3 KVAC
1.5 KVAC / 1.5 KVAC
1.5 KVAC / 500 VAC
Degree of protection
IP20
Class of protection
Class I with PE connection
MTBF
> 1,000,000hrs.
Type of housing
Aluminium (AI5052)
Dimensions (L / W / H )
121mmx32mmx125mm
Weight
0.37Kg
STATUS Indicator
LED (6) DC OUTPUT OK
YES (GREEN LED)
Climatic Data
Ambient temperature (Operating)
Ambient temperature (Storage)
-20°C to 80°C (> 50°C de-rating)
-25°C to 85°C
Humidity at 25°C, non-condensing
< 95% RH
Vibration (Non-Operating)
10Hz to 500Hz @ 30 m/ S
2
(3G peak); displacement of 0.35mm;
60min per axis for all X, Y, Z direction. in acc. with IEC 68000-2-6.
Shock (in all directions)
30G (300m/S
2
) in all directions according to IEC60068-2-27
Pollution degree
2 according to EN50178
Climatic class
3K3 according to EN 60721
In conformance with EMC guideline 89/336/EEC and low
voltage directive 73/23/EEC
EMC (electromagnetic compatibility)
DINRAIL 1AC / 24V DC / 2.5A (EOE11010248)
Immunity to interference according to EN 61000-6-2
EN 61000-4-2
1)
Housing
Discharge of static electricity (ESD) Contact discharge:
Air Discharge:
LEVEL 4
8 KV
15 KV
EN 61000-4-3
1)
Housing
Radiate Field Immunity Frequency/Field intensity:
LEVEL 3
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation
EN 61000-4-4
1)
Fast transients (Burst):
2KV
4)
EN 61000-4-5
1)
Surge voltage Immunity (Surge):
2KV
3)
/ 2KV
4)
(Level 3)
EN 61000-4-6
1)
I/O:
Conducted Immunity Frequency / U
o
:
Level 3
0.15MHz - 80MHz / 10Vrms.
EN 61000-4-11
2)
Voltage dips
Input: Main Buffering > 20ms.
Noise emission according to EN 61000-6-3
Emitted radio interface
Radio interference voltage
EN55011 (EN55022) CLASS B
5
EN55011 (EN55022) CLASS B
5
EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EN 61000 corresponds to IEC 61000
1) Criterion A: Normal operating behavior within the defined limits.
2) Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
3) Symmetrical: Conductor to conductor.
4) Asymmetrical: Conductor to ground.
5) Class B: Area of application industry and residential.