D-Link DES1226 Switch User Manual


 
DES-1218/DES-1226 10/100/1000 Mbps Ethernet Switch User’s Guide
15
5
5 S
WITCH
M
ANAGEMENT
This chapter discusses the features used to manage the Switch, and explains important
points regarding these features. Configuring the Switch is discussed in detail.
Local Console Management
Local console management involves the administration of the Switch via a direct
connection to the RS-232 DCE console port. This is an Out-Of-Band connection,
meaning that it is on a different circuit than normal network communications, and thus
works even when the network is down.
The local console management connection involves a terminal or PC running terminal
emulation software to operate the switch’s built-in console program. Using the console
program, a network administrator can manage and control the functions of the Switch.
Console port (RS-232 DCE)
Out-of-band management requires connecting a terminal, such as a VT-100 or a PC
running terminal emulation program (such as HyperTerminal, which is automatically
installed with Microsoft Windows) a to the RS-232 DCE console port of the Switch.
Switch management using the RS-232 DCE console port is called Local Console
Management to differentiate it from management done via management platforms,
such as D-View, HP OpenView, etc.
The console port is set for the following configuration:
Baud rate: 9,600
Data width: 8 bits
Parity: none
Stop bits: 1
Flow Control None
Make sure the terminal or PC you are using to make this connection is configured to
match these settings.
If you are having problems making this connection on a PC, make sure the emulation is
set to VT-100. You will be able to set the emulation by clicking on the File menu in you
HyperTerminal window, click on Properties in the drop down menu and click the
Settings tab, here you will find the Emulation options. If you still don’t see anything,
try hitting <Ctrl> + r to refresh the screen.