Maintenance
The air lter unit of this projector consists of a lter cover, two kinds of lters, and
a lter frame. The new double large lters system is expected to function longer.
However, please check and clean it periodically to keep ventilation needed for
normal operation of the projector.
When the indicators or a message prompts you to clean the air lter, comply with
it as soon as possible. Replace the lters when they are damaged or too soiled.
To prepare new lters, make contact with your dealer and tell the following type
number.
Cleaning and replacing the air lter
Type number : MU06481 (Filter set)
1.
Turn the projector off, and unplug the power cord.
Allow the projector to sufciently cool down.
2.
Use a vacuum cleaner on and around the lter cover.
3.
While supporting the projector with one hand, use
your other hand to pull the lter cover forward in the
direction of the arrow.
4.
Use a vacuum cleaner for the lter vent of the
projector and the outer side of the lter unit.
5.
Take the lters out while holding the lter cover.
7.
Put the lters back into the lter cover.
Put the coarse meshed lter into a lter cover
rst. Then put the ne meshed lter on the coarse
meshed one, turning its stitched side up.
8.
Put the lter unit back into the projector.
When you replace the lamp, please replace the air lter. An air lter of specied
type will come together with a replacement lamp for this projector.
(continued on next page)
Filter cover
Filter unit
Filter cover
Filter (ne meshed)
Filter (coarse meshed)
2
4
3
7
Stitched
side
6.
Use a vacuum cleaner on both sides of the lters.
When vacuuming up the ne meshed lter, hold it
so it will not be sucked in. If the lters are damaged
or heavily soiled, replace them with the new ones.