64
Maintenance
The air lter unit of this projector consists of a lter cover, two kinds of lters, and
a lter frame. The new double large lters system is expected to function longer.
However, please check and clean it periodically to keep ventilation needed for
normal operation of the projector.
When the indicators or a message prompts you to clean the air lter, comply with
it as soon as possible. Replace the lters when they are damaged or too soiled.
To prepare new lters, make contact with your dealer and tell the following type
number.
Cleaning and replacing the air lter
Type number : MU06481 (Filter set)
1.
Turn the projector off, and unplug the power cord.
Allow the projector to sufciently cool down.
2.
Use a vacuum cleaner on and around the lter cover.
3.
While supporting the projector with one hand, use
your other hand to pull the lter cover forward in the
direction of the arrow.
4.
Use a vacuum cleaner for the lter vent of the
projector and the outer side of the lter unit.
5.
Take the lters out while holding the lter cover.
7.
Put the lters back into the lter cover.
Put the coarse meshed lter into a lter cover
rst. Then put the ne meshed lter on the coarse
meshed one, turning its stitched side up.
8.
Put the lter unit back into the projector.
When you replace the lamp, please replace the air lter. An air lter of specied
type will come together with a replacement lamp for this projector.
(continued on next page)
Filter cover
Filter unit
Filter cover
Filter (ne meshed)
Filter (coarse meshed)
2
4
3
7
Stitched
side
6.
Use a vacuum cleaner on both sides of the lters.
When vacuuming up the ne meshed lter, hold it
so it will not be sucked in. If the lters are damaged