Elation Professional XM485-V1.0-NR All in One Printer User Manual


 
24
some error in channel 1. If there are some errors on channel 1, channel 5, channel 6 at the same time, you may
see the error message “Err channel is Color wheel”, “Err channel is Pan movement”, “Err channel is Tilt
movement” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture remain
error message after performing reset more than 2 times, only the channels which have errors can not work
properly, others can work as usual. Please contact with dealer or manufacturer for service, self repair is not
allowed.
PAN- movement Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-
indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving
IC on the main PCB). The PAN- movement is not located in the default position after the reset.
TILT- movement Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driving IC on the main PCB). The TILT- movement is not located in the default position after the reset.
Color wheel Er
(Color wheel- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The color wheel is not located in the default position after the reset.
Gobo wheel 1 Er
(Gobo wheel 1 - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The Gobo wheel 1 is not located in the default position after the reset.
Gobo Rot 1 Er
(Gobo Rot 1- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The Gobo Rot 1 is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must not be
corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling,
suspension, trussing).
3) Mechanically moved parts must not show any traces of wearing and must not rotate with
unbalances.
4) The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and
any safety problems have to be removed.
In order to make the lights in good condition and extend the life time, we suggest a regular
cleaning to the lights.
1) Clean the inside and outside lens each week to avoid the weakness of the lights due to
accumulation of dust.
2) Clean the fan each week.
3) To make sure the smooth gobo rotation, we suggest adding proper lube to the wheel each
three month, avoiding the excessive lube splashes during the gobo rotating.
4) A detailed electric check by approved electrical engineer each three month, make sure that the
circuit contacts are in good condition, prevent the poor contact of circuit from overheating.
XM485-V1.0-NR