EMC FC5300 Network Hardware User Manual


 
3
3-4
EMC Fibre Channel Storage-System Configuration Planning
Planning File Systems and LUNs with Shared Switched Storage
The storage-system disk IDs and server Storage Group LUNs are as
follows.
With 36-Megabyte disks, the LUN storage capacities and drive names
are as follows.
File Server 288 Gbytes on two LUNs
Unit U on five disks bound as a RAID 5 Group for
144 Gbytes of storage; for file storage.
Unit V on five disks bound as a RAID 5 Group for
144 Gbytes of storage; for file storage.
Clustered System LUNs
Database Server LUNs (DS) - SP A
File Server LUNs (FS) - SP B Mail Server LUNs (MS) - SP A
Disk IDs
RAID type, storage type
4_0-4_4 RAID 5, Files A
4_5-4_9 RAID 5, Files B
Disk IDs
RAID type, storage type
2_0-2_4 RAID 5, ISP A mail
2_5-2_9 RAID 5, ISP B mail
3_0-3_4 RAID 5, Users
3_5-3_9 RAID 5, Specs
Disk IDs
RAID type, storage type
0_0, 0_ 1 RAID 1, Log file for
database Dbase1
0_4-0_9 RAID 5 (6 disks), Dbase1
1_0-1_4 RAID 5, Users
1_5-1_9 RAID 5, Dbase2
6_0, 6_1 – Hot spare (automatically replaces a failed disk in any server’s LUN)
FS R5
FilesA
FS R5
FilesB