Emerson 510 Surge Protector User Manual


 
Su
r
ge Pr
otectiv
e D
e
vi
ces
Ins
t
al
la
tion,
Opera
tion and
M
ai
nt
en
an
c
e
M
an
u
al
9
IO
-
70103
Re
v 0, 1/2013
MONIT
OR
I
NG F
EA
TUR
ES
Ext
ernal
Stat
us Indica
tor
s (
St
andard)
Th
es
e indic
at
or
s
pr
ovi
de
a
sum
mary of
the
status of
the
su
r
ge
S
PD
modul
e
.
F
or no
rm
al
c
onditions, the gre
e
n
OK LED is
illumi
na
t
ed and the
red
Ser
vi
ce
LED
is
ex
tinguishe
d.
If
the
su
r
ge
S
PD
or
module requir
e
s r
eplacemen
t, the gre
e
n
OK
LED is tu
r
ned
o
ff and the red
Ser
vi
ce
LED illumi
na
ted.
A
udible
Alarm
(St
andard
/Optional
)
If
the
su
r
ge
S
PD
module
requir
e
s r
eplacemen
t, an audible a
lar
m
may be
ac
ti
vat
ed
t
o dr
a
w
atten
tion
t
o the
fact t
ha
t r
ep
air
ser
vi
c
e is
required
t
o r
est
ore the
s
ys
te
m
t
o no
rm
al op
era
tion. An
audible a
lar
m disable is pr
ovi
ded
t
o sil
enc
e the a
lar
m. The
s
ys
te
m will au
to
ma
tically r
es
e
t it
se
lf
after rep
ai
r.
The
audible
alarm s
wi
tc
h
and
Ser
vi
ce
LED
can
be
te
st
ed
b
y a
c
ti
va
ting
the Test s
wi
tc
h on the
s
ys
te
m moni
t
or
p
an
e
l.
Summa
ry
Alarm
C
on
tact (St
andard
/Optional
)
One or
two se
ts
of
sum
mar
y a
lar
m
For
m C r
e
la
y
contac
ts (
N.
O
. and
N.C.) are pr
ovi
ded
f
or
remote
indic
a
tion
of
the
f
ailed
su
r
ge
S
PD
modul
e. Contac
ts are
rat
ed
5
am
ps at
250
VAC
m
axi
m
um
with
a p
ow
er fact
or
of
1.0.
Acc
es
s to
the
contac
ts
is
pr
ovi
ded
via contact ter
mi
n
als loc
at
ed ins
i
de
o
f
the unit s c
ov
er.
Surge
C
oun
t
er
(
Optional
)
The
su
r
ge
c
ou
nter
is
pr
ovi
ded
f
or transi
en
t
v
ol
t
age su
r
ge moni
tor
ing. The
c
ou
nte
r
to
t
al
ize
s
line su
rge
s moni
t
ored sin
c
e the
la
st time the
c
ou
nte
r
wa
s
r
es
e
t. The
c
ir
c
uit
c
ou
n
ts all su
rge
s t
ha
t d
ev
ia
t
e from the line
sine
w
av
e
. The
factor
y
se
tting is 30%
ov
e
r nomi
n
al line
v
ol
t
ag
e
.
O
th
e
r
se
ttin
g
s in
c
lude 50%, 70%, and 100%.
TROUBLESHOOTIN
G/
SE
R
VIC
I
NG/ MA
I
NTENANCE
T
roubl
e
sho
o
tin
g
If s
tatu
s
f
ailure indic
a
tion oc
cur
s or sum
mar
y a
lar
m
contac
ts
ha
ve
ch
anged s
ta
te
, a q
u
alified
e
le
ctrici
an s
h
all fi
r
st
deter
mine
i
f the
s
ys
te
ms
v
ol
t
age and prop
e
r p
ha
sing
e
xists.
If
the
S
PD
rem
ains
in
an
alarm c
ond
ition
on
ce
the
e
le
ctrici
an is
sa
tisfied t
ha
t
the
e
le
ctr
ical
s
ys
tem
and
its
c
onne
c
tions
are no
rm
al, the unit should be r
ep
aire
d.
At
this
poi
nt c
onsult
the
factory,
ha
ving
av
ai
l
able
the
f
oll
o
wing i
nfor
ma
tio
n:
Unit
iden
tific
a
tion numb
er
(r
e
fe
rs to
the
mod
el
and
seri
al numb
er
s d
et
ailed on the
da
t
a
l
ab
e
l and is
loc
at
ed on the fro
n
t
o
f the
enclo
sur
e
.)
Na
ture
o
f probl
e
m
(in
c
luding s
tatu
s
o
f all s
tatu
s
indic
at
or
s and a
lar
ms).
Se
r
vi
c
ing
The
Emerson Network Power 5
10 Series c
om
es
with
a
ten ye
ar
war
ra
nt
y.
F
or
ser
vi
c
ing
as
sis
t
an
ce
,
contac
t
y
our
local Sal
e
s
Re
pr
es
enta
ti
v
e or Em
ers
on N
etwor
k
P
ow
er
,
Su
r
ge Pr
otec
tion
a
t
800
-
288
-
6169 or 607
-
721
-
8840.
ON
L
Y Q
U
AL
IFI
ED
PER
SONNEL SHOULD
P
ER
F
ORM
MA
I
NTENANCE ON THE
SY
STE
M.
HA
Z
ARDOUS
VOLTA
GE
S ARE
PRE
SENT
I
NS
I
DE THE
UNI
T
D
UR
I
NG NORMAL O
P
ER
A
TION
S.
EL
EC
TRI
C
AL
S
AF
ET
Y
PRE-CA
UTIONS MUST BE
F
OL
LO
WED WHEN SE
R
VIC
I
NG T
H
IS U
NIT.
T
O
PRE
VENT RISK OF EL
EC
TRI
C
AL SHOCK, TURN
OFF AND
L
OCK OUT ALL P
O
WER SOU
RCE
S
T
O THE
UN
IT BE
F
ORE SE
R
VIC
I
NG U
NIT.
C
orre
c
ti
v
e Main
t
enan
c
e
-
The
Emerson Net
work Power
51
0 Series
S
PD is d
esi
gned
f
or
year
s
o
f troubl
e-
free
op
era
tion. H
owe
ver
,
eve
n the m
o
st r
eli
able equipm
en
t
ma
y
f
ail und
e
r abno
rm
al
c
onditions. D
i
agn
o
stic indic
at
or
s are
pr
ovi
ded
t
o indic
at
e wh
e
n the unit needs r
ep
air or
replacemen
t.
T
o
e
nsure
con
tinui
t
y
o
f su
r
ge pr
otec
tion,
f
ailed units should be r
ep
aired or r
eplac
ed
a
t the
ear
li
e
st
co
nv
e
ni
ent ser
vi
ce
oppo
r
tuni
ty.
Wh
en replac
ing
su
r
ge
modul
e
s,
o
th
e
r
c
ompon
en
ts should be in
s
pe
ct
ed
f
or
dam
age and r
eplac
ed
i
f ne
c
es
sa
ry
.
St
an
dar
d
e
le
ctr
ical
troubl
e
sh
oo
ting pro
c
edur
es
should
be
us
ed
to iso
la
te
probl
e
ms
o
th
er th
an
f
ailed su
r
ge
curren
t di
verte
r modul
e
s.
Wh
e
n r
eplac
ing
c
ompon
en
ts, use
iden
tically r
at
ed
c
ompon
en
ts
f
or
con
tinued prop
e
r op
era
tion and s
afety
.
Pl
eas
e
contac
t
factor
y
f
or i
nfor
ma
tion on r
eplacemen
t
par
ts.
Pr
ev
en
t
ati
v
e Main
t
enan
c
e (Inspe
c
tion and
Cle
aning)
-
Per
iodic
s
ys
te
m in
s
pe
c
tions,
cle
aning, and
c
onne
c
tion
c
hecks are re
c
omm
e
nded
t
o
e
nsure r
eli
able
s
ys
te
m
perform
an
c
e and
con
tinued su
r
ge transi
en
t pr
otec
tion.
It
is
di
ffi
c
ult
to est
ablish
a
sc
h
edule
f
or
pr
eventa
ti
v
e
m
ai
nten
an
ce
sin
ce c
onditions
vary
from
si
te to
si
te.
In
s
pe
c
tions
f
or
f
ailed su
r
ge modul
e
s
u
sing
av
ai
l
able
di
agn
o
sti
c
s should be done routin
e
ly (
wee
kly or mo
n
thly).