Emerson ACGY1110808 Surge Protector User Manual


 
Whi
l
e e
v
e
r
y precaution has been taken to ensure accuracy and
c
om
pl
e
t
e
ne
s
s in this lit
erature, Liebert Corporation assumes no
r
esponsibility, and disclaims all liability for damages resulting
f
r
om u
s
e o
f this information or for any errors or omissions.
© 2006 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
o
f their respective owners.
® Liebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
SL-22070 (R10/06) Printed in USA
Bu
siness-Critical Continuity, Emerson Network
P
o
w
e
r an
d the Eme
rson Network Power logo
are trademarks and service marks of Emerson
Electric Co. ©2006 Emerson Electric Co.
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
800 877 9222
Phone (U.S. &
Canada Onl
y)
614 888 0246
Phone (Outside U.S.)
614 841 6022
FAX
Via
Leonardo Da Vinci 8
Zona
Industriale Tognana
35028
Piove Di Sacco (PD)
Ital
y
39 049 971
9 111 Phone
39 049 584
1 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 G
loucester Rd, Wanchai
Hong
Kong
852 25722201 Phone
852 2802
9250 FAX
liebert.com
Technical Support
800 288 6169 Toll-Free
607 724 2484 Phone
607 722 8713 Fax
How To Order
Liebert AccuGuide
®
Voltage configuration:
Wye (Y), Delta (D), Split Phase (S)
Modes of protection:
111-All modes for Y system
110-line to line, line to ground
101-line to neutral, neutral to ground
Liebert AccuGuide lengths:
5 feet 8 feet 10 feet 12 feet 15 feet 20 feet
Pigtail gauge:
No. 6 AWG No. 8 AWG No. 10 AWG
Note: 5 feet of pigtail length will be provided on each
side of the Liebert AccuGuide assembly. Please specify
pigtail gauge (conduit nipple to SPD connection/conduit
nipple to power source connection).
How to construct an AccuGuide
(ACG) model # Code
1. Liebert AccuGuide ACG
2. Voltage configuration Y
3. Mode of protection 111
4. Liebert AccuGuide length: 8 feet 08
5. Pigtail gauge: No. 8 AWG 08
Sample model #: ACGY1110808
Required conduit size: 1 ⁄2" to 2"
Liebert AccuGuide Coax Construction
O
rdering Information:
L
iebert AccuGuide cable assemblies are available
in s
everal standard lengths for any service
c
onfiguration with up to seven modes of
p
rotection. The conductor gauge is configured
to accommodate the system.
Primary &
Secondary
Insulation
Jacket
Outer Braid
Inner Braid
Conductor
General Specifications
Voltage (VAC) 0 to 600
Operating frequency (Hz) 0 to 400
Altitude (m) 18,000 feet
Operating temperature (°C) -40 to +90
Operating humidity (%) 0 to 95 (non-condensing)
Flame resistance VW-1
DC resistance (mΩ/ft/mode) ≤ 1.3
Warranty 5-years
Safety agency approval UL Listed Wire Assembly Kit
Patent number 5,384,429