519
The Parallel POD
e
n
a
b
les paralleling of two Liebert GXT2 10 kVA UPS
m
odules to double capacity to 20kVA. A third unit
may be added to configure the system for N+1
redundancy, raising system reliability.
High capacity, compact on-line UPS with flexible output voltage and power distribution.
RACK-MOUNT UPS
3
Other Product Features Of Liebert GXT2 6 & 10 kVA
UPS Models Include:
■
Wider input voltage window enables the UPS to support the critical
lo
ad without having to transfer to battery
■
Patented output neutral bonding feature meets UL 1778 standard
by providing a method for maintaining the UPS output neutral to
ground bond in all modes of operation
■
Internal bypass assures continuity of power to critical loads during
system problems or maintenance
■
Automatic frequency detection matches line input frequencies of
either 60 or 50 Hz
■
User-replaceable hot swappable internal batteries provide five
minutes of runtime at full load
■
Additional battery cabinets available for extended backup time
■
Liebert IntelliSlot
®
communications port utilizes Liebert IntelliSlot
®
Web Card to provide SNMP and web-based management
L
iebert Power Monitoring Capabilities
The operation of the UPS can be monitored using:
■
Liebert MultiLink
®
Automated System Shutdown Software
■
Li
e
be
r
t Nform Monitoring System
■
Li
ebert Universal Monitor and Remote Power Monitor Panels
■
Third-Party Monitoring Systems
For more information, see pages 40 and 41.
User replaceable
hot swappable
internal batteries
Liebert GXT2 6 & 10 kVA UPS systems provide true
on-line protection in the smallest cabinets in their
capacity range. The UPS systems offer internal
batteries, unlimited extended external batteries, and
internal bypass capability, resulting in continuous
uptime for the connected equipment. This makes
the UPS an ideal fit in applications where the
power requirements are demanding—but rack
space is limited.
Application versatility is achieved through the use of
a dual inverter design capable of providing
simultaneous output voltages of 240/120, 208/120,
230/115, 220/110, or 200/100 VAC. The input is
power factor corrected to approximately .98,
enabling the UPS to power a wide variety of
equipment with different voltages.
For installation flexibility, you may choose from
several different wiring configurations made possible
b
y the use of removable power distribution boxes
that simply plug into the rear of the UPS. Options
include hardwired or receptacle connections, as well
as maintenance bypass capabilities.
Liebert GXT2 6 & 10 KVA On-Line UPS