EN
TERP
R
I
SE UPS
4
23
Cutting-Edge Power Technology
Makes The Difference
Liebert NX UPS Systems Incorporate A
Number Of Other Exceptional
Features:
■
High overload rating handles 125% for 10
minutes, 150% for one minute and a 1000%
overload for 10 milliseconds
■
Digital controls provide the fastest possible power
management to enhance reliability, accuracy and
efficiency
■
Front access for easy installation and servicing of
unit
■
Compact footprint requires less floor space,
leaving you with more room for other equipment
■
Redundancy options
■
M
odules designed to share load based on percent
rating
■
Load Bus Synchronization standard on models
with Softscale technology
■
So
f
t S
wit
c
hin
g t
echnology increases efficiency by
up to 2% and saves energy
■
Integrated ground fault detection allows for
e
ff
ec
tive transformer-less design while saving
space and lowering the weight
■
Parallel for redundancy or capacity
■
Parallel like or unlike capacity units for wider
growth range (requires Softscale technology)
■
Active input rectifier is generator and utility
fr
i
e
n
dl
y
■
Web card monitoring standard
■
S
t
ar
t up standard
■
O
ne year warranty
■
One year remote monitoring/reporting
Softscale
™
technology, paralleling capabilities and Eco-mode
™
, all
contribute to lower initial, incremental and operating costs.
Liebert NX 40-120 kVA UPS Systems
Softscale Technology
Liebert NX 40-120 kVA UPS systems are available with Liebert
Softscale technology that provides flexibility to increase UPS capacity
by 20 or 40kVA without changes in your infrastructure. Allows
paralleling of unlike-sized models for capacity or redundancy.
Designed for optimized performance with the same high efficiency at
40% utilization as at 100% utilization.
Paralleling Capabilities
Liebert NX 40-120 kVA systems allow you to parallel UPS modules for
capacity and redundancy, eliminating the batteries as a single point
of failure because each UPS has its own isolated battery. Liebert NX
also features integrated dual bus synchronization as a standard
feature on models with Softscale technology. This provides the
capability to synchronize the outputs of two independent UPS
modules when they are configured as a redundant system feeding
independent distribution paths.
E
c
o
-M
od
e H
igh Efficiency Configuration
To save energy, this operating mode switches the UPS to static bypass
dur
in
g nor
mal operation. When power problems are detected the
UPS a
utomatically switches back to double conversion mode.
L
i
ebert NX Maintenance Bypass And
Distr
ibution Cabinet
The o
ptional Liebert NX Maintenance Bypass and Distribution Cabinet
converts the UPS system’s 480VAC output to 208/120VAC. This
cabinet is available in capacities of 75kW and 125kW covering the
Liebert NX UPS range of 40-120kVA. The front and back door panels
and the on-unit monitor panel are matched to the UPS unit. Power
an
d c
on
tr
ol cabling from this cabinet to the UPS is included,
enhancing ease of installation and availability. For ease of installation
an
d maintenance, the cabinet offers top or bottom cable entry and
requires only front and back.
Paralleling
C
abinet
Battery
Cabinet
UPS