Enterasys Networks 6H3xx Switch User Manual


 
System Resources Information Screen
Module Configuration Menu Screens 5-31
Field Descriptions
Refer to Table 5-8 for a functional description of each screen field.
5.7.1 Setting the Reset Peak Switch Utilization
To set the Reset Peak Switch Utilization field to YES or NO, proceed as follows:
1. Use the arrow keys to highlight the Reset Peak Switch Utilization field.
2. Press the SPACE bar to select YES or NO.
3. Use the arrow keys to highlight the SAVE command at the bottom of the screen.
4. Press ENTER. The message “SAVED OK” displays and the Reset Peak Utilization counter
resets to zero.
Table 5-8 System Resources Information Screen Field Descriptions
Use this field… To…
CPU Type
(Read-Only)
See which microprocessor is used in the switch module.
Flash Memory
Installed
(Read-Only)
See the amount of FLASH memory that is installed in the switch
module and how much is currently available.
DRAM Installed
(Read-Only)
See the amount of DRAM installed in the switch module and how
much of it is currently available.
NVRAM Installed
(Read-Only)
See the amount of NVRAM that is installed in the switch module and
how much of it is currently available.
Current Switch
Utilization
(Read-Only)
See what percentage of the module switching capacity is currently
being used.
Peak Switch
Utilization
(Read-Only)
See the peak percentage of module switching capacity used, since the
last reset.
Reset Peak Switch
Utilization
(Toggle)
Reset the Peak Switch Utilization field. The switch may be set to either
YES or NO as described in Section 5.7.1. YES resets the Peak Switch
Utilization field to the current system utilization.