Enterasys Networks VSER-RPU-SYS Power Supply User Manual


 
Notice
iii
BSMI EMC Statement — Taiwan
This is a class A product. In a domestic environment this product may cause radio interference
in which case the user may be required to take adequate measures.
Safety Compliance
Please read the following safety information carefully before installing the
RPS:
WARNING: Installation and removal of the unit must be carried out by qualified personnel only.
The unit must be connected to an earthed (grounded) outlet to comply with international
safety standards.
Do not connect the unit to an A.C. outlet (power supply) without an earth (ground)
connection.
The appliance coupler (the connector to the unit and not the wall plug) must have a
configuration for mating with an EN 60320/IEC 320 appliance inlet.
The socket outlet must be near to the unit and easily accessible. You can only remove power
from the unit by disconnecting the power cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions according to
IEC 60950. The conditions are only maintained if the equipment to which it is connected also
operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
supplies. If your supplies are of IT type, this unit must be
powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point
labelled Neutral, connected directly to earth (ground).
Impédance à la terre