Note
•
Buffer full recovery timing (DIP switch
3-2
and
3-3)
and DTR flag set/X-off transmit timing (DIP switch
3-6)
selections are enabled only when buffer operation
is enabled (DIP switch
3-1
is
OFF).
If
SW3-1
is
ON,
buffer full recovery timing
is
set to 32 bytes and DTR
flag set/X-off transmit timing
is
set to 16 bytes.
• DSR/DCD
signals (DIP switch
3-5)
are enabled when
RS-232D
is
selected.
Buffer full
recovery
timing
When the available space for bytes in the print buffer
drops to 512 or 16 bytes,
data
entry is disabled. As the
printer prints the
data
in
the buffer, the vacant area for
bytes increases. When this vacant area reaches one of the
four values listed in the table below,
data
communication
is
resumed. These settings are selectable by using the
DIP switches.
Table 10. Buffer full
recovery
timing
Vacant area for bytes
DIP switch
in
the print buffer
SW
3-2
SW 3-3
768
OFF
OFF
1024
OFF
ON
2048
ON
OFF
4096
ON ON
13