Epson emp-tw10h Projector User Manual


 
Projector Care-23
Appendices
Appendix.fm3/9/04
fResetting the lamp operating time
The projector has a built-in counter which keeps track of the lamp operating time and causes the replacement warning
message to be displayed when the cumulative operating time reaches a certain point. Therefore, the counter needs to be
reset from the configuration menu, after the lamp has been replaced with a new one.
1
Turn on the power and press the
[Menu] button.
2
Select "Lamp-Hours Reset" from the
"Reset" menu, using the [u][d][e]
buttons.
3
Use the [l][r] buttons to select "Yes",
then press the [e] button.
The lamp operating time will be reset.
p
Install the lamp securely. If the lamp cover is removed, the lamp turns off automatically as a safety precaution. The lamp
will not turn on if the lamp or the lamp cover is not installed correctly.
After replacing the lamp, be sure to reset the lamp operating time.
The lamp contains mercury. Dispose of used lamps properly in accordance with your local regulations.
p
Please do not reset the lamp operating time except when the lamp has been changed. Otherwise, the lamp operating time will
not be displayed correctly.
USERS_E.BOOK Page 23 Tuesday, March 9, 2004 12:52 PM