Epson P07303 Network Router User Manual


 
9
5.7. Software Status Setting
When system POWER ON, there is no need to turn off to modify Command Type, Baud Rate, Parity,
Demo Mode and International Character. To re-set DIP Switch to various Command Type under
the following list of Command to modify the setting. The setup value will stored in the EEPROM.
When DIP Switch is OFF. Next time the system POWER ON previous setup value will be the
default value and no need to modify.
5.7.1. Baud rate
STX 05 B n ETX /Set baud rate and keep it with EEPROM/
ASCII Format STX 05 B n ETX
Dec. Format [02][05][66] n [03]
Hex. Format [02h][05h][42h] n [03h] 30hn34h
Description Change the display communication baud rate. The baud rate setting can be
selected from 4800 to 38400.
N Baud rate
30h 4800
31h 9600
32h 19200
33h 38400
5.7.2 International character set
STX 05 S n ETX /Change international character set/
ASCII Format STX 05 S N ETX
Dec. Format [02][05][83] n [03]
Hex. Format [02h][05h][53h] n [03h] 30hn3fh
Description Change the display international character font .A total of 16 different character
fonts to select from. The setting function will be saved to EEPROM.