Epson RP-300 Printer User Manual


 
Page - 15-
6. Specifications
Important!
When using a printer power supply other than optional AC adaptor (HT-U1135, LSE
9901B2460), be sure that the following cautions are observed.
Use a power supply of DC 24V± 10% and more than 1.5A.
Be careful about installing the printer in an area where there is noise.
Take the appropriate measure to protect against electrostatic AC line noise, etc.
6-1. Environmental Requirments
(1)Operating
Temperature 5°C to 45°C
Humidity 10% to 90% RH (without condensation)
(2)Transport/Storage (except paper)
Temperature -20°C to 60°C
Humidity 10% to 90% RH (without condensation)
6-2. Reliability
(1)MCBF 50 million lines (based on an average printing rate of 12.5% with paper
thickness in the range 65µm to 75µm)
35 million lines (based on an average printing rate of 12.5% with paper
thickness in the range 76µm to 150µm)
(2)Head Life 100 million pulses, 100Km
(3)Cutter Life 1.0 million cuttings (if the paper thickness is between 65 and 90µm)
6-3. Certification
(1)FCC PART15 CLASS A
(2)CE EMCD/LVD
(3)UL/cUL