Extron electronic DVS 605 Switch User Manual


 
Upgrading the Firmware Using the Web Pages
The onboard rmware version of the DVS 605 unit can be upgraded via the factory-installed web pages when connected via the
Ethernet port to a LAN or WAN, using a web browser such as Microsoft Internet Explorer.
Firmware upgrade les (with an EFF or ESS extension) for the DVS 605 unit are available at www.extron.com. At the website, browse
to the le location and download the latest rmware version to a PC connected to the DVS 605.
Access the DVS 605 internal web pages by entering the IP address of the unit in the browser Address eld.
When the web pages open do the following:
1. Click the Hardware button above the global navigation bar.
2. Click the Firmware Loader icon on the global navigation bar. The Firmware Loader screen opens.
3. Click Browse. The Choose File to Upload dialog box opens.
4. Browse to and select the downloaded firmware file to upload to the device. Valid firmware files have an EFF or ESS extension.
5. Click Open. This closes the dialog box and returns you to the Firmware Loader screen.
6. Click Upload. Uploading progress is displayed and will indicate when completed.
7. When the upload is complete the unit reboots. Any IP connections to the unit need to be re-established.
4
DVS 605 • Setup Guide (Continued)
Basic SIS Commands Table
The DVS 605 can be congured with specic SIS commands via an RS-232, USB, or LAN connection. This table lists a selection of
the commands. For a full list of SIS commands and variables see the DVS 605 User Guide, online at www.extron.com.
Command ASCII command
(host to scaler)
Response
(scaler to host)
Additional description
Select video and audio input
X!
! In
X!
All
]
Selects video and audio from input
X!
.
Select video input
X!
& In
X!
RGB
]
Selects video only from input
X!
.
Select audio input
X!
$ In
X!
Aud
]
Selects audio only from input
X!
.
Execute Auto-Image
0*A Img0
]
Executes Auto-Image for current input.
Mute video to black
1B
Vmt1
]
Mutes video and display a black screen.
Mute video and output sync
2B Vmt2
]
Mutes video and sync output.
Unmute video
0
B
Vmt0
]
Unmutes video.
PIP on
EX!PIP} PipX!]
Turns on PIP and displays input
X!
.
PIP off
E
0
PIP} Pip
00
]
Turns off PIP.
Swap
%
Tke
]
Swaps inputs between main and PIP windows, or current and
previous input when not in PIP mode.
Recall PIP preset (without input)
3*X2@ .
3RprX2@]
Recalls PIP preset
X2@
without input.
Recall PIP preset (with input)
4*X2@ .
4RprX2@]
Recalls PIP preset
X2@
with input.
Save PIP preset
4*X2@ ,
4SprX2@]
Saves PIP preset
X2@
.
Enable Executive mode 1
1X Exe1
]
Locks out entire front panel.
Enable mode 2
2X Exe2
]
Allows limited front panel adjustments only.
Disable Executive mode
0X Exe0
]
Allows all front panel adjustments and selections.
View front panel lock status
X 0
]
(or 1
]
)
(or 2
]
)
Shows executive mode status.
NOTE: Changes made to all Ethernet settings do not take effect until the reboot networking command (2BOOT) is issued.
Set DHCP to Off or On
EX1&DH} IdhX1&]
Sets DHCP mode (default setting is 0 = off).
View DHCP status
EDH}
X1&]
Shows DHCP setting.
Set IP address
EX1(CI} IpiX1(]
Sets IP address to
X1(
(default IP is 192.168.254.254)
View IP address
ECI}
X1(]
Shows current IP address
X1(
.
Reboot network
E2BOOT} Boot2]
Restarts network after IP address or DHCP changes.
NOTE:
X!
= Input number (1 – 5)
X1&
= DHCP mode: 0 = Off (default), 1 = On
X1(
= IP address, such as 192.168.254.254 (default)
X2@
= PIP presets (1-16)
68-2110-50
Rev.C
06 13
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron Asia
+65.6383.4400
Extron China
+86.21.3760.1568
Extron Korea
+82.2.3444.1571
Extron Europe
+31.33.453.4040
Extron Japan
+81.3.3511.7655
Extron Middle East
+971.4.2991800
Extron India
+91.80.3055.3777
© 2013 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com