Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
IP setup
Set IP address
EX1#
CI
}
Ipi
X1#]
Read IP address
E
CI
} X1#]
Set subnet mask
EX1#
CS
}
Ips
X1#]
Read subnet mask
E
CS
} X1#]
Set gateway IP address
EX1#
CG
}
Ipg
X1#]
Read gateway IP address
E
CG
} X1#]
Set DHCP on or off
EX1$
DH
}
Idh
X1$]
Read DHCP on/off status
E
DH
} X1$]
Set verbose mode
EX1%
CV
}
Vrb
X1%]
Read verbose mode
E
CV
} X1%]
Congure current port timeout
E
0*
X1^
TC
}
Pti0*
X1^]
Read current port timeout
E
0TC
} X1^]
Congure global IP port timeout
E
1*
X1^
TC
}
Pti1*
X1^]
Read global IP port timeout
E
1TC
} X1^]
N
X1#
= IP address ###.###.###.###
X1$
= DHCP 0 =1 off, 1 = on
X1%
= Verbose mode 0 = clear/none (default for Telnet connection)
1 = verbose mode (default for RS-232/RS-422 connection)
2 = tagged responses for queries
3 = verbose mode and tagged for queries
X1^
= Port timeout interval 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
Installing and Starting the Control Program
Several useful Windows
®
-based programs are available on the
Extron Software Products CD-ROM that is included with the
switcher, including the DSP Congurator program and the
Matrix Switchers Control Program. These programs are also
available on the Extron Web site, www.extron.com.
The DSP Congurator program is required for full operation of
most of the switcher's DSP functions and to save partial presets.
It also provides some limited control of the switcher's non-DSP
functions. Refer to the MPX Plus, 866 A User's Manual and the
program Help le for more information.
The Matrix Switchers Control Program is another way to
operate the switcher's more basic, non-DSP, functions.
Run either program on a PC connected to either of the
switcher’s serial ports or the Ethernet port. See
l
,
m
, and
o
,
on pages 2-5, for connection information. The program must be
installed on a Windows-based computer and cannot be run from
the CD.
N
For details on operating the programs, refer to the
MPX Plus 866 A User's Manual, chapter 5, “Matrix
Software”.
Installing the programs
1. Insert the CD-ROM into the drive. The installation
program should start automatically.
The Extron software CD window appears.
N
If the installation program does not self-start, run
Launch.exe from the CD.
2. Click the Software tab.
MPX Plus 866 A • Remote Control
Remote Control, cont’d
4-10
MPX Plus 866 A • Remote Control
4-11