Extron electronic QSD 204 Switch User Manual


 
Serial Communication, cont’d
QSD 204 • Serial Communication3-6
Enable (lock image adjustments) 1X Exe1 Lock front panel adjustments;
adjust image via RS-232 only.
View the executive mode status X Exe
X16
Show executive mode status.
Example: X Exe0
Firmware version, part number & information requests
Query firmware version number Q Ver
X8
Show the controller firmware
version.
Request part number N N60-501-0_
Show the decoder’s part #.
Request general info. I (See below) Show the decoder’s status.
C
X1
•Typ
X4
•Std
X12
•Sdi
X1
Zap (reset to default settings)
Zap image adjustments/controls
Esc
zI ZapI Reset the image adjustments
to factory settings.
Zap all QSD 204 settings/memories
Esc
zXXX ZapXXX Reset everything: all settings,
and adjustments to the factory
default.
Command/response table for SIS commands (continued)
Command ASCII Command Response Additional description
(host to decoder) (decoder to host)