Extron electronic YCV 100 Switch User Manual


 
YCV 100, VYC 100N, VYC 100P • Installation and Operation
YCV 100, VYC 100N, VYC 100P • Installation and Operation
Installation and Operation, cont’d
2-9
Power Supply
Output Cord
SECTION A–A
Ridges
Smooth
AA
Orange Captive Screw
Connector
Tie Wrap
3/16”
(5 mm) Max.
Strip the insulation from the wires to expose 5 mm
(3/16") of the conductors. Do not tin the stripped power
supply leads before installing the captive screw
connector. Tinned wires are not as secure in the captive
screw connectors and could be pulled out.
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.
To verify the polarity before connection, check the no load
power supply output with a voltmeter.
4
Power LED — Lights to indicate that the VYC 100N/VYC 100P
is on.
2-8
VYC 100N and VYC 100P
The VYC 100N and VYC 100P have identical rear panel
connectors.
VYC 100N
COMPOSITE
VIDEO
DECODER
POWER
VIDEO IN
S-VIDEO OUT
Y
C
12V
0.5A MAX
1
3
4
2
1
Input connector — Connect a composite video source to this
female BNC connector.
2
Output connectors — Connect an S-video output device to:
• the two female BNC connectors and/or
• the 4-pin mini DIN connector.
3
Power connector — An external 12 V power supply is included
with the unit. Plug it into this 2-pole captive screw connector.
Wire the connector as shown in the following illustration.
CAUTION
When connecting the power supply, voltage
polarity is extremely important. Applying power
with incorrect voltage polarity could damage the
power supply and the VYC 100N/VYC 100P.
Identify the power cord negative lead by the ridges
on the side of the cord or a black heat shrink
wrapping around it.
Strip the insulation from the wires to expose 5 mm
(3/16") of the conductors. Do not tin the stripped power
supply leads before installing the captive screw
connector. Tinned wires are not as secure in the captive
screw connectors and could be pulled out.
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.
To verify the polarity before connection, check the no load
power supply output with a voltmeter.
4
Power LED — Lights to indicate that the YCV 100 is on.