Falcon SG800-1T Power Supply User Manual


 
SG Series
TM
UPS PLUS
®
800VA to 1.5kVA
Model Number
SG800-1T
SG1K-1T
SG1K-2T
SG1.5K-1T
Nominal VA
800
1000
1000
1500
Electrical Input
Nominal AC Voltage
120V
120V
230V
120V
AC Voltage Range
87-140V
87-140V
170-275V
87-140V
Current-Amps
5.5
6.9
3.6
10.7
Frequency
50/60 Hz ± 5% (Auto – Tracking)
Power Factor Correction
> 0.95
Efficiency (Typical)
> 86%
Electrical Output
Watts
560
700
700
1050
AC Voltage
(Switchable)
100V
110V
115V
120V
100V
110V
115V
120V
200V
220V
230V
240V
100V
110V
115V
120V
Frequency
50/60 Hz (Auto Tracking)
Frequency Stability
±0.3% (Battery Mode)
Voltage Regulation
± 2%
Step Load Change
± 7% for 100% load variation
Harmonic Distortion
< 3% Linear Load, < 5% Non -Linear Load
Overload
105% load for 50 Seconds
Crest Ratio
3:1
Battery
DC Voltage
36V
72V
Type
12V, 7AH Sealed Lead Acid Maintenance-Free
Back Up Time @ Full Load
@ 1/2 Load
9 Minutes
25 Minutes
6 Minutes
19 Minutes
11 Minutes
30 Minutes
Recharge Time
8 Hours to 90%
Battery times are approximate.
Transfer Time
Line Fails/Recovers
Zero
UPS to Bypass or Reverse
< 4ms
After Overload
Auto Transfer to UPS
Electrical Connections
Input
6’ Cord with
5-15P
6’ Cord with
5-15P
6’ Cord with
Schuko or 6 -15P
6’ Cord with
5-15P
Output
(6) 5-15R
(6) 5-15R
(4) IEC 320
(6) 5-15R
Contact the factory for other input/output options.
Environmental
Operating Temperature
0º C - 40º C (32º F to 104º F)
Humidity
10% to 95% Non – Condensing
Altitude
7,000 Feet
Cooling
Low Velocity Forced Air Fans
Audible Noise @ 1 Meter
<45dBA
< 50dBA
Controls and Indicators
LED
Line, Inverter, Battery Reserve, Load, Bypass, Alarm, Crest, Battery & Load Capacity Level
Audible Alarms
DC Mode, Low Battery, Over/Under Voltage, Over/Under Frequency, High Temp., Over Load, Fau lt Alarm
Communications
RS-232 Serial Port (Bundled UPSilon 2000 Software)
Mechanical
Dimensions H x W x D inches
(mm)
8.7 x 6.0 x 15.8
(220.9 x 152.4 x 401.3)
13.8 x 7.6 x 18.9
(350.5 x 193.0 x 480 .0)
Weight lb. (kg)
33 (14.9)
68 (30.9)
Agency Listing
UL 1778, CUL,
FCC Class A
CE available with Schuko
plug only
UL 1778, CUL,
FCC Class A
Available Options
Option A
60 Hz to 50 Hz Frequency Conversion
Option B
50 Hz to 60 Hz Frequency Conversion
Option C
SNMP/HTTP Network Card (Internal)
Option D
Standard Contact Closure Interface Card
Maintenance Bypass
Make-Before-Break External Wrap Around
External Battery Packs
Extended Run Time Battery Packs (minut es to hours)
Fast Battery Charger
Fast Charger internal to the Extended Battery Pack Cabinet (Required for battery times 2 hours or more.)
23