Falcon SG800-2T Power Supply User Manual


 
BATTERY OPTION
MODELS
W/O Charger
SGB2S7-1K3
SGB4S7-1K3
SGB5S7-1K3
SGB10S7-1K6
SGB10S7-1K6
BATTERIES
6 Pieces 12V, 7AH
12 Pieces 12V, 7AH
15 Pieces 12V,
7AH
30 Pieces 12V, 7AH
60 Pieces 12V,
7AH
BATTERIES IN UPS
3 each of 12V, 7AH
# of CASES
Inches
(mm)
1 Mini-Tower
13.8 x 7.6 x 18.9
(350 x 193 x 480)
1 Mini-Tower
13.8 x 7.6 x18.9
(350 x 193 x 480)
1 Mini-Tower
13.8 x 7.6 x18.9
(350 x 193 x 480)
1 Floor Standing
32.1 x 10.2 x 21.8
(814 x 259 x 554)
2 Floor Standing
32.1 x 10.2 x 21.8
(814 x 259 x 554)
RUN TIME @ 100W
215 Min.
390 Min.
480 Min.
960 Min.
2000 Min.
RUN TIME @ 200W
107 Min.
210 Min.
255 Min.
520 Min.
1070 Min.
RUN TIME @ 400W
49Min.
96 Min.
120 Min.
255 Min.
550 Min.
RUN TIME @ 700W
23Min.
50 Min.
80 Min.
140 Min.
260 Min.
CHARGER OPTION INFORMATION
BATTERY OPTION
MODELS
With 120Vac Charger
SGB2S7-1K3-1
SGB4S7-1K3-1
SGB5S7-1K3-1
SGB10S7-1K6-1
SGB10S7-1K6-1
BATTERY OPTION
MODELS
With 200-240Vac
Charger
SGB2S7-1K3-2
SGB4S7-1K3-2
SGB5S7-1K3-2
SGB10S7-1K6-2
SGB10S7-1K6-2
CHARGER OUTPUT
41.1Vdc @ 4.5A
41.1Vdc @ 4.5A
41.1Vdc @ 4.5A
41.1Vdc @ 4.5A
41.1Vdc @ 4.5A
# OF CHARGERS
1
1
1
2
4
SG800VA-3kVA TOWER EXTENDED BATTERY BANK SELECTION GUIDE
FOR 800VA-1KVA MODELS
BATTERY OPTION
MODELS
W/O Charger
SGB2S7-2K3
SGB2S7-2K3
SGB5S7-2K6
SGB2S7-2K3
SGB5S7-2K6
SGB5S7-2K6
BATTERIES
12 Pieces of 12V,
7AH
24 Pieces of 12V,
7AH
30 Pieces of 12V,
7AH
36 Pieces of 12V,
7AH
60 Pieces of 12V,
7AH
90 Pieces of 12V,
7AH
BATTERIES IN UPS
6 each of 12V, 7AH
# of CASES
Inches
(mm)
1 Mini-Tower
13.8 x 7.6 x 18.9
(350 x 193 x 480)
2 Mini-Towers
13.8 x 7.6 x 18.9
(350 x 193 x 480)
1 Floor Standing
32.1 x 10.2 x 21.8
(814 x 193 x 554)
3 Mini-Towers
13.8 x 7.6 x 18.9
(350 x 193 x 480)
2 Floor Standing
32.1 x 10.2 x 21.8
(814 x 193 x 554)
3 Floor Standing
32.1 x 10.2 x 21.8
(814 x 193 x 554)
RUN TIME @ 300W
170 Min.
310 Min.
390 Min.
470 Min.
760 Min.
1200 Min.
RUN TIME @ 500W
95 Min.
180 Min.
225 Min.
260 Min.
465 Min.
690 Min.
RUN TIME @ 700W
63 Min.
120 Min.
155 Min.
185 Min.
320 Min.
490 Min.
RUN TIME @ 1000W
39 Min.
79 Min.
100 Min.
120 Min.
215 Min.
330 Min.
RUN TIME @ 1400W
24 Min.
51 Min.
64 Min.
80 Min.
140 Min.
225 Min.
CHARGER OPTION INFORMATION
BATTERY OPTION
MODELS
With 120Vac
Charger
SGB2S7-2K3-1
SGB2S7-2K3-1
SGB5S7-2K6-1
SGB2S7-2K3-1
SGB5S7-2K6-1
SGB5S7-2K6-1
BATTERY OPTION
MODELS
With 208-240Vac
Charger
SGB2S7-2K3-2
SGB2S7-2K3-2
SGB5S7-2K6-2
SGB2S7-2K3-2
SGB5S7-2K6-2
SGB5S7-2K6-2
CHARGER OUTPUT
82.5Vdc @ 4A
82.5Vdc @ 4A
82.5Vdc @ 4A
82.5Vdc @ 4A
82.5Vdc @ 4A
82.5Vdc @ 4A
#. OF CHARGERS
1
1
1
1
2
3
FOR 1.5KVA-2KVA MODELS
BATTERY OPTION
MODELS
W/O Charger
SGB2S7-3K3
SGB2S7-3K3
SGB5S7-3K6
SGB2S7-3K3
SGB5S7-3K6
SGB5S7-3K6
BATTERIES
16 Pieces 12V,7AH
32 Pieces 12V, 7AH
40 Pieces 12V, 7AH
48 Pieces 12V, 7AH
80 Pieces 12V, 7AH
160 Pieces 12V, 7AH
BATTERIES IN UPS
8 each of 12V, 7AH
# of CASES
H x W x D
Inches
(mm)
1 Mini-Tower
13.8 x 7.6 x 18.9
(350 x 193 x 480)
2 mini-Towers
13.8 x 7.6 x 18.9
(350 x 193 x 480)
1 Floor Standing
32.1 x 10.2 x 21.8
(814 x 259 x 554)
3 Mini-Towers
13.8 x 7.6 x 18.9
(350 x 193 x 480)
2 Floor Standing
32.1 x 10.2 x 21.8
(814 x 259 x 554)
4 Floor Standing
32.1 x 10.2 x 21.8
(814 x 259 x 554)
RUN TIME @ 500W
135 Min.
260 Min.
310 Min.
380 Min.
640 Min.
1350 Min.
RUN TIME @ 1000W
59 Min.
115 Min.
140 Min.
170 Min.
300 Min.
620 Min.
RUN TIME @ 1500W
33 Min.
68 Min.
84 Min.
105 Min.
190 Min.
400 Min.
RUN TIME @ 2100W
20.5 Min.
43 Min.
57 Min.
69 Min.
125 Min.
270 Min.
CHARGER OPTION INFORMATION
BATTERY OPTION
MODELS
With 120Vac Charger
SGB2S7-3K3-1
SGB2S7-3K3-1
SGB5S7-3K6-1
SGB2S7-3K3-1
SGB5S7-3K6-1
SGB5S7-3K6-1
BATTERY OPTION
MODELS
With 208-240Vac
Charger
SGB2S7-3K3-2
SGB2S7-3K3-2
SGB5S7-3K6-2
SGB2S7-3K3-2
SGB5S7-3K6-2
SGB5S7-3K6-2
CHARGER OUTPUT
110Vdc @4.5A
110Vdc @4.5A
110Vdc @4.5A
110Vdc @4.5A
110Vdc @4.5A
110Vdc @4.5A
# OF CHARGERS
1
1
1
1
2
4
FOR 3KVA MODELS
8
NOTE: The backup times stated are for reference only. Backup time may vary due to the type of load, battery age or condition,
environmental conditions, etc.