Measures to prevent the unit from toppling or dropping should be taken for safety reasons and accident prevention
during emergencies including earthquakes.
When mounting this unit on a pedestal or ceiling, remove the 4 feet on the bottom surface and use all the 4 screw
holes (M5 screws) to mount.
.........................................................................................................
Precautions for Mounting
zSpecial expertise and techniques are required for
mounting this unit. Be sure to ask your dealer or a
specialist to perform mounting.
zDepth of the screw holes (screw length) is 30 mm. Use
screws shorter than 30 mm but longer than 19 mm.
Using other screws will result in malfunctioning or
cause the unit to drop.
zWhen mounting to a pedestal, ensure sufficient space
(foot height of 21.5 mm or higher) around the unit so that
the air inlets are not blocked.
zDo not tilt this unit more than ±5 degrees from side to side
when using. This may result in uneven colors or shortening
of lamp life.
zRegardless whether the unit is still under guarantee, Meridian
is not liable for any product damage caused by mounting
the unit with non-approved ceiling fittings or when the
environment is not suitable for ceiling-mount.
zWhen using the unit hanging from a ceiling, pay attention
to the surrounding temperature. When a heater is in use,
temperature around the ceiling is higher than expected.