FTLX1461E2 Product Specification – October 2008
© Finisar Corporation – October 2008 Rev B Page 8
Environmental Performance
Operating case temperature: 0°C to +70°C
Operating humidity: 0% -95% RH non-condensing
Fibers and Connectors
The transponder has SC receptacles for both Tx and Rx. The transponder is designed for single
mode SC cables, 0° polished endface (PC).
70-pin Connector
The module interface connector is a 70-pin, printed circuit board edge connection with a 0.5 mm
pitch. The appropriate mating connector for the customer PCB is a 70-pin SMT, dual row, right
angled, edge connector, 0.5 mm pitch (Tyco Electronics part number 1367337-1, Molex part
number 74441-0003 or equivalent).
Rail Requirement
The XENPAK rail system required to mount the XENPAK module is fully defined by the MSA.
Aqueous Wash
Finisar XENPAK transponders are neither solderable nor aqueous washable and are not
intended for these processes.
VI. Regulatory Compliance
Feature Standard Comments
ESD:
Electrostatic Discharge to the
Electrical Pins (HBM)
EIA/JESD22-A114-B
(MIL-STD 883D
Method 3015.7)
Class 1a (> 500 V)
Immunity:
Against Electrostatic Discharge
(ESD) to the Module Receptacle
EN 61000-4-2
IEC 61000-4-2
Discharges ranging from
±2 kV to ±25 kV to
the front end / faceplate / receptacle cause no
damage to module (under recommended
conditions).
Immunity:
Against Radio Frequency
Electromagnetic Field
EN 61000-4-3
IEC 61000-4-3
With a field strength of 10 V/m, noise
frequency ranges from 10 MHz to 2 GHz. No
effect on module performance between the
specification limits.
Emission:
Electromagnetic Interference
(EMI)
FCC 47 CFR
Part 15, Class B
EN 55022 Class B
CISPR 22
Noise frequency range:
30 MHz to 40 GHz
Radiated emission does not exceed specified
limits when measured inside a shielding
enclosure with MSA conform cutout.