Fortinet 5001FA2-LENC Network Card User Manual


 
FortiGate-5001FA2-LENC Security System Guide
18 01-30000-76602-20080606
Troubleshooting Hardware installation
5 Open the left and right handles to their fully open positions.
Opening the handles slides the board a short distance out of the slot,
disconnecting the board from the chassis backplane.
The IPM LED turns blue. All other LEDs turn off.
6 Pull the board about half way out.
All LEDs turn off.
7 Turn both handles to their fully-closed positions.
When the handles are fully-closed they lock into place.
8 Carefully slide the board completely out of the slot.
Troubleshooting
This section describes the following troubleshooting topics:
FortiGate-5001FA2-LENC does not startup
FortiGate-5001FA2-LENC cannot display chassis information
FortiGate-5001FA2-LENC does not startup
Positioning of FortiGate-5001FA2-LENC handles, the presence or absence of a
functioning shelf manager, incorrect jumper settings and firmware problems may
all prevent a FortiGate-5001FA2-LENC board for starting up correctly. This section
describes how to find and fix each of these problems.
All chassis: left handle not contacting power switch
The left handle activates the FortiGate-5001FA2-LENC board power switch.
Open
Fully Open
Alignment Pin
Handle
Handle
Close
Fully Closed
and Locked
Alignment Pin
Alignment Pin
Handle