2-3
2.1.2 Refitting the Shipping Bracket:
Whenever you need to move the Scanner to a new location it is advisable to
refit the shipping bracket to avoid causing damage to the Scanners’ internal
mechanism. Please follow the instructions below to refit the shipping bracket.
i). Turn off the Scanner power at the power on/off switch.
ii). Open the document cover.
iii). Turn off the Scanner.
Note: For steps (iv) to (vi) please refer to figure 2-1 and 2-2
iv). Carefully place the Scanner in an upright position on its front side.
v). Use a suitable screwdriver to remove the screw holding the shipping
bracket in the use position.
vi). Put the shipping bracket into the shipping position, with the long side
extending into the Scanner base. Secure it with the screw.
vii). Carefully place the Scanner back into its normal position.
2.2 SCSI Interface Device ID
When you have several devices on a SCSI chain, you may need to adjust
the SCSI ID selector setting located on the back of the Scanner. This setting assigns a
specific "device ID" to the Scanner. If the assignment conflicts with an existing SCSI
device, please select a new ID. (See Figure 2-3)
Note: The factory setting for Scanner is ID 6. Usually, ID 0 is assigned to an internal
hard disk drive, and ID 7, to SCSI adapter or host. ID 8 and 9 are not in actual
use.
Using a suitable tool, turn the selector switch until the arrow points to the desired ID
number.