If using PW008GE4/PW0G8GE1/PW008GE5/PW0G8GE2 and using SCS2.3 or later, this operation is not
required. And, if using PW008QG1 and using SCS2.5.1 or later, this operation is not required.
#
cp /cdrom/cdrom0/FJSVgid_2.4/fjgi_s.dat /opt/FJSVcsl/etc/scsidata/fjgi_s.dat
#
cp /cdrom/cdrom0/FJSVgid_2.4/fjgi_t.dat /opt/FJSVcsl/etc/scsidata/fjgi_t.dat
#
cp /cdrom/cdrom0/FJSVgid_2.4/fjgi_q.dat /opt/FJSVcsl/etc/scsidata/fjgi_q.dat
2. When you use GigabitEthernet on "SynfinityCluster" or "PRIMECLUSTER", please refer to "Appendix C.3
Note" in "FUJITSU PCI GigabitEthernet 2.4 User's Guide" for detailed information about the setting and
notes.
3. When the installation program is finished, the system must be rebooted.
4. After you reboot the system, environment setting is needed. Refer to
"FUJITSU PCI GigabitEthernet 2.4
User's Guide" for detailed information about the setting.
6.4 Removing the Software
1. Log in to your system as superuser.
# su <Return>
2. Type pkgrm(1M) command.
(1) In case of using on PRIMEPOWER1 or PRIMEPOWER100
# pkgrm FJSVgid <Return>
(2) In case of using on other machines
*Solaris 2.6 OS :
# pkgrm FJSVgid <Return>
*Solaris 7 OS :
# pkgrm FJSVgid <Return>
# pkgrm FJSVgidx <Return>
*Solaris 8 OS :
# pkgrm FJSVgid <Return>
# pkgrm FJSVgidx <Return>
# pkgrm FJSVgidr <Return>
# pkgrm FJSVgidad <Return>
*Solaris 9 OS :
# pkgrm FJSVgid <Return>
# pkgrm FJSVgidx <Return>
# pkgrm FJSVgidr <Return>
# pkgrm FJSVgidad <Return>
*Solaris 10 OS:
# pkgrm FJSVgid <Return>
# pkgrm FJSVgidad <Return>
7