2
FBR211 SERIES
n COIL DATA CHART
MODEL
Nominal
Nominal
Coil
current
Must
Must Maximum
Nominal
Coil
A type B type resistance
(at nominal
operate release allowable
temperature
voltage
(±10%)
voltage)
voltage voltage voltage
power
rise
Flux free
Plastic sealed
Flux free
Plastic sealed
approx.
FBR211SAD001-n FBR211NAD001-n FBR211SBD001-n FBR211NBD001-n
1.5 VDC 5 Ω 300 mA
FBR211SAD003-n FBR211NAD003-n FBR211SBD003-n FBR211NBD003-n
3 VDC 20 Ω 150 mA
FBR211SAD005-n FBR211NAD005-n FBR211SBD005-n FBR211NBD005-n
5 VDC 56 Ω 89 mA
70% max. 10% min. 150% of Approx. Approx.
FBR211SAD006-n FBR211NAD006-n FBR211SBD006-n FBR211NBD006-n
6 VDC 80 Ω 75 mA of nominal of nominal nominal 450 mW 45 deg
voltage voltage voltage (at nominal (at nominal
FBR211SAD009-n FBR211NAD009-n FBR211SBD009-n FBR211NBD009-n
9 VDC 180 Ω 50 mA voltage) voltage)
FBR211SAD012-n FBR211NAD012-n FBR211SBD012-n FBR211NBD012-n
12 VDC 320 Ω 38 mA
FBR211SAD024-n FBR211NAD024-n FBR211SBD024-n FBR211NBD024-n
24 VDC 1,280 Ω 19 mA
Note: All values in the table are measured at 20°C.
MODEL
Nominal
Nominal
Coil
current
Must
Must Maximum
Nominal
Coil
C type E type resistance
(at nominal
operate release allowable
temperature
voltage
(±10%)
voltage)
voltage voltage voltage
power
rise
Flux free
Plastic sealed
Flux free
Plastic sealed
approx.
FBR211SCD001-n FBR211NCD001-n FBR211SED001-n FBR211NED001-n
1.5 VDC 12 Ω 125 mA
FBR211SCD003-n FBR211NCD003-n FBR211SED003-n FBR211NED003-n
3 VDC 45 Ω 67 mA
FBR211SCD005-n FBR211NCD005-n FBR211SED005-n FBR211NED005-n
5 VDC 120 Ω 42 mA
70% max. 10% min. 225% of Approx. Approx.
FBR211SCD006-n FBR211NCD006-n FBR211SED006-n FBR211NED006-n
6 VDC 180 Ω 33 mA of nominal of nominal nominal 200 mW 25 deg
voltage voltage voltage (at nominal (at nominal
FBR211SCD009-n FBR211NCD009-n FBR211SED009-n FBR211NED009-n
9 VDC 400 Ω 23 mA voltage) voltage)
FBR211SCD012-n FBR211NCD012-n FBR211SED012-n FBR211NED012-n
12 VDC 700 Ω 17 mA
FBR211SCD024-n FBR211NCD024-n FBR211SED024-n FBR211NED024-n
24 VDC 2,800 Ω 9 mA
2. HIGH SENSITIVITY (C or E type)
1. STANDARD (A or B type)
Note: All values in the table are measured at 20°C.