3.2 Cleaning the ADF
fi-4530C Image Scanner Operator’s Guide 57
DAILY CARE
3
• Feed rollers
1) Open the ADF while pushing down the ADF button. If you open the ADF cover
when the indication of the Function No. display is "P" or "0", the Feed rollers do
not rotate even you perform the operation of step 2) below. So open the ADF cover
when the indication is not "P" or "0".
2) Simultaneously hold down the "Send to" and "Scan" buttons on the operator panel.
The Feed rollers rotate a little. For details on locations of the "Send to" and "Scan"
buttons, refer to "1.3 Operator panel" in fi-4530C Getting Started on the Setup CD-
ROM.
3) Hold a lint-free dry cloth moistened with the Cleaner F1 against the surfaces of the
rotating Feed rollers so that it lightly cleans their surfaces. Take particular care in
cleaning these rollers as black debris on them adversely affects pickup perfor-
mance. As a guideline, seven presses of the "Send to" and "Scan" buttons rotates
the Feed rollers one full turn.
• Plastic rollers
Clean the Plastic rollers lightly, not to roughen the roller surfaces. Take particular care in
cleaning these rollers as black debris on them adeversely affects the pickup performance.
Be careful no to damage the sponges beside the rollers.
Function No.
display
Function
Send to
Scan
LED