Fujitsu MAP3735 Computer Drive User Manual


 
Sense Data Error Recovery Methods
5 - 16 C141-E167
Table 5.3 Sense data error classification (3 of 4)
K* C* Q* Outline of Error L*
Recovery Method
(See Table 4.4.)
5 20 00 Invalid command o
p
eration code None 2
21 00 Logical block address out of range
24 00 Invalid field in CDB
25 00 Logical unit not supported
26 00 Invalid field in parameter list
There is an error in the command specification
contents.
5 3D 00 Invalid bits in IDENTIFY messa
g
e None 3
90 00 Initiator's SCSI ID not identified
An error was detected in the SCSI protocol in the
command execution sequence.
6 29 xx Power on, reset, or BUS DEVICE RESET occurred None 14
The IDD was initialized by a Power on, RESET
condition or BUS DEVICE RESET message.
6 2A 01 Mode parameters changed None 21
The MODE SELECT parameters were changed by
another INIT.
6 2F 00 Commands cleared by another INIT None 25
Commands were cleared by another INIT.
6 3F 01 Microcode has been changed None 27
02 Changed operation definition
6 5B 01 Log exception (Threshold condition met) None 26
The current cumulative value exceeded the current
threshold value.
02 Log count at maximum
The current cumulative value reached the
maximum value.
6 5C 01 Spindle synchronized None 22
Rotational synchronization was completed.
6 5C 02 Spindle not synchronized None 23
Rotational synchronization deviated.
7 27 00 Write
p
rotected None 15
Access to a read protected or write protected.
7 2C 00 Command sequence error None 2
The SET LIMITS command was issued 2 times
within a group of commands linked in a series.
* K: Sense Key C: Sense Code
Q: Sub-sense code L: Logging Necessary? (shown in Section 5.2.3)