Command Specifications
3 -
78
C141-E167
(3) Format parameters
Figure 3.13 shows the data format of the Format parameter transferred from the INIT when “1” is
specified in the “FmtData (format data)” bit of the CDB.
Header
Bit
Byte
76543210
0 X‘00’
FOV DPRV DCRT STPF
1000000Immed0
10/10/1
×
2 Defect List Length (MSB)
3 Defect List Length (LSB)
Defect List (D List)
Bit
Byte
76543210
0
1
Defect Descriptor 0
x
xx
xx+1
xx+x
Figure 3.13 FORMAT UNIT command parameter list configuration
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~