Fujitsu MBA3073RC Computer Drive User Manual


 
Diagnostics and Maintenance
72 C141-E252
6.2.5 Tests
This HDD can be tested in the following ways:
Initial seek operation check (See Subsection 6.3.1)
Operation test (See Subsection 6.3.2)
Diagnostic test (See Subsection 6.3.3)
Figure 6.1 shows the flow of these tests.
Test results OK?
Start
Execute an operation
test using a host
computer or test
equipment
Yes
N
o
Yes
N
o
Start self-test by
turning the power on
Test results OK?
Continue operation
Check host system
(Table 6.2)
Host system
normal?
Analyze system-related
error
Replaced or repair
HDD
HDD
normal?
Execute diagnostic
test using a host
computer or test
equipment
Test results OK?
Test using voltage or
temperature stress
Test results OK?
Normal
Analyze HDD
error (Table 6.3)
Yes
Yes
N
o
N
o
Yes
N
o
Yes
N
o
Figure 6.1 Test flowchart