Fujitsu MHW2040BS Computer Drive User Manual


 
Interface
(35) READ NATIVE MAX ADDRESS (X’F8’)
This command posts the maximum address intrinsic to the device, which can be
set by the SET MAX ADDRESS command. Upon receipt of this command, the
device indicates the maximum address in the DH, CH, CL and SN field. Then
reports the status to the host system.
Error reporting conditions
(1) A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block Registers setting contents)
CM
1 1 1 1 1 0 0 0
DH
x L x x xx
CH
CL
SN
xx
SC
FR
xx
xx
xx
xx
At command completion (Shadow Block Registers contents to be read)
ST Status information
DH x x x x Max head/LBA [MSB]
CH
CL
SN
SC
ER
CYL No. [MSB] / LBA
CYL No. [LSB] / LBA
SCT No. / LBA[LSB]
xx
Error information
5-136 C141-E249