Fujitsu MHW2080BS Computer Drive User Manual


 
Interface
Table 5.20 Data format of SMART Comprehensive Error Log
Byte First sector Next sector
00 SMART Error Logging 01h Reserved
01 Index Pointer Latest Error Data Structure Reserved
02…5B
1
st
Error Log Data Structure
Error Log Data Structure 5n+1
5C…B5
2
nd
Error Log Data Structure2
Error Log Data Structure 5n+2
B6…10F
3
rd
Error Log Data Structure3
Error Log Data Structure 5n+3
110…169
4
th
Error Log Data Structure4
Error Log Data Structure 5n+4
16A…1C3
5
th
Error Log Data Structure5
Error Log Data Structure 5n+5
1C4…1C5 Total number of drive errors Reserved
1C6…1FE Reserved Reserved
1FF Check sum Check sum
“n” indicates sector number in the Error Log. The first sector is 0.
SMART Self-Test
The host computer can issue the SMART Execute Off-line Immediate sub-command
(Features field = D4h) and cause the device to execute a self-test. When the self-test
is completed, the device saves the SMART self-test log to the disk medium.
The host computer can issue the SMART Read Log Sector sub-command
(Features field = D5h, Sector Number field = 06h, Sector Count field = 01h) and
can read the SMART self-test log.
5-68 C141-E249