Fujitsu MPB3052AT Computer Drive User Manual


 
C141-E045-02EN1 - 6
Table 1.3 Current and power dissipation
Typical RMS current (*1) [mA]
+12 V +5 V
Model MPB
3021AT
MPB
3032AT
MPB
3043AT
MPB
3052AT
MPB
3064AT
All Models MPB
3021AT
MPB
3032AT
MPB
3043AT
MPB
3052AT
MPB
3064AT
Spin up 1300
1500 peak
460
600 peak
17.9
Idle (Ready)
(*3)
115 140 185 460 3.68 3.98 4.52
R/W (On Track)
(*4)
125 150 200 510 4.05 4.35 4.95
Seek (Random)
(*5)
335 360 410 510 6.57 6.87 7.47
Standby 4 155 0.82
Sleep 4 110 0.60
*1 Current is typical rms except for spin up.
*2 Power requirements reflect nominal values for +12V and +5V power.
*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any
commands. A portion of the R/W circuitry is powered down, the spindle motor is up to
speed and the Drive ready condition exists.
*4 R/W mode is defined as 50% read operations and 50% write operations on a single
physical track.
*5 Seek mode is defined as continuous random seek operations with minimum controller
delay.
Typical Power (*2) [watts]
Mode of
Operation