IPS42 Internal Power Supply Installation and User Guide (11/09)
3
www GarrettCom com
..
Cooling Method:
All IPS42 models feature convection cooling for temperature un-controlled locations. All
models have closed cases to withstand dirt and use special thermal techniques to transfer
heat to the outside of the case for cooling.
ALARM RELAY Terminal Block, four screw terminals:
Internal 60VA relay contact: Open for power Off, closed for power On (Hardware).
Mounting options
Metal mounting clips for panel mounting: included
DIN-Rail mounting option: Model # DIN-RAIL-MC2 (see Section 3.1)
Mean Time Between Failure (MTBF) – over 15 years, Telcordia (Bellcore) Method