Gefen EXT-DPKVM-241 Switch User Manual


 
10
How to Resolve IR Code Con icts
In the event that IR commands from other remote controls con ict with the
supplied RMT-2IR remote control, changing the remote channel will alleviate
this issue. The RMT-2IR remote control and the 2x1 DisplayPort KVM both have
banks of DIP (Dual Inline Package) switches for con guring the remote channel
that both units use to communicate. These settings must exactly match each
other for proper operation.
The DIP switch bank on the RMT-2IR is located underneath the battery cover.
DIP switch banks for the 2x1 DisplayPort KVM are located on the underside of
the unit beneath a black piece of metallic tape. Switches 1 and 2 on the RMT-2IR
directly correspond to DIP Switches 1 and 2 on the 2x1 DisplayPort KVM. Only
switches 1 and 2 (of 4 in that bank) are used for IR Code settings.
Remote Channel 1:
Default
1 2
Remote Channel 2:
1 2
Remote Channel 3:
1 2
Remote Channel 4:
1 2
Left: Picture of the opened rear battery
compartment of the RMT-2IR remote showing
the exposed DIP Switch bank between the
battery chambers.
2x1 DisplayPort KVM DIP Switch Settings
Remote Channel 1:
Default
Remote Channel 4:
1
2
3
4
1
2
3
4
Remote Channel 3:
1
2
3
4
Remote Channel 2:
1
2
3
4
INFRARED (IR) CODE CHANNEL CONFIGURATION