Gefen GEF-3GSDI-16416 Switch User Manual


 
7
PANEL DESCRIPTIONS
Back Panel
1 Reference In Connector
Connect an external reference to this connector. Bi-level (black burst) and tri-
level sync are supported.
2 3G-SDI Output Ports (1 - 16)
Connect 3G-SDI monitors to these ports.
3 Grounding Terminal
Provides a discharge path to ground in case a short circuit occurs between the
“hot” lead of the power supply and the enclosure of the Matrix. The grounding
wire should be attached from the grounding terminal to an approved ground
path.
4 RS-232 Serial Port
Connects to the RS-232 control device. The 16x16 3GSDI Matrix may be
switched remotely using this port. See page 16 for more information.
5 IP Control Interface
Connect the 16x16 3GSDI Matrix to a network in order to use IP control.
6 110/220 AC Power Receptacles
Connect one power cord to both power receptacles. The redundant (secondary)
power cable should be connected to an electrical outlet on a different circuit.
7 Fuse Drawer
Each power receptacle houses a fuse drawer. Within each fuse drawer are two
(2) 250 V fuses. One fuse is active and the other is a spare.
8 3G-SDI Input Ports (1 - 16)
Connect 3G-SDI source devices to these ports.
9 Reference Loop Connector
Reference Loop connector.