POWER REQUIREMENTS
POWER REQUIREMENTSPOWER REQUIREMENTS
POWER REQUIREMENTS
Input Power Requirements
(typ)
110 VAC 3.6A/394W; 220VAC 1.9/385W
Max Input Power
100-240 VAC, 50/60 Hz., 4.5-1.9A; 48-60 VDC 10.4A/8.3A
Heat Dissipation
1622 BTU/hr
TEMPERATURE AND HUMIDITY RANGES
TEMPERATURE AND HUMIDITY RANGESTEMPERATURE AND HUMIDITY RANGES
TEMPERATURE AND HUMIDITY RANGES
Operating Temperature
41°F to 104°F (5oC to 40°C)
Shipping Temperature
-40°F to 158°F (-40°C to 70°C)
Operating Humidity
10% to 90% RH @ 104°F (40°C) non-condensing
Non-Operating Humidity
Up to 93% RH @ 104°F (40°C)
DECLARED ACOUSTIC NOISE LEVELS
DECLARED ACOUSTIC NOISE LEVELSDECLARED ACOUSTIC NOISE LEVELS
DECLARED ACOUSTIC NOISE LEVELS
Sound Power
< 6.5 Bels
Sound Pressure
< 57 dBA
SHOCK AND VIBRATION
SHOCK AND VIBRATIONSHOCK AND VIBRATION
SHOCK AND VIBRATION
Shock, Operational
5G's for 11 milliseconds, half sine
Shock, Non-Operational
15G 11ms half sine
Vibration, Operational
5-500Hz, 0.21Grms flat spectrum0.000089g2/HZ Random Vibration
Vibration, Non-
Operational
5-500-5Hz, 0.5 G peak to peak, sinusoidal
PHYSICAL
PHYSICALPHYSICAL
PHYSICAL
Height
3.436 in/ 8.727 cm
Depth (excluding cables)
(back of ear to back of
controller handle)
MSA2024: 20.28 in / 51.510 cm
MSA2012: 21.8 in. / 55.372 cm
Width (body only)
17.55 in / 44.58 cm (w/ ears 19 in / 48.26 cm)
Chassis Weight
(no controllers)
MSA2012 chassis: 44 lbs. MSA2024 chassis: 43 lbs
Modular SAN Array
Modular SAN ArrayModular SAN Array
Modular SAN Array
2300fc G2 Controller
2300fc G2 Controller2300fc G2 Controller
2300fc G2 Controller
User Interface
User InterfaceUser Interface
User Interface
- Status and activity provided via management interfaces Status Indicators on
front of Controller
RAID Support
RAID SupportRAID Support
RAID Support
0, 1, 3, 5, 6, 10, 50
Cache Memory
Cache MemoryCache Memory
Cache Memory
1GB Read/Write. ECC protection with backup to Flash memory (indefinite
backup)
Cache Backup
Cache BackupCache Backup
Cache Backup
ECC protection with back up to flash memory (indefinite backup)
Upgradeable Firmware
Upgradeable FirmwareUpgradeable Firmware
Upgradeable Firmware
yes
Disk Drive and Enclosure
Disk Drive and EnclosureDisk Drive and Enclosure
Disk Drive and Enclosure
Protocol Support
Protocol SupportProtocol Support
Protocol Support
3 Gb SAS - Serial Attached SCSI / 3 Gb SATA II
Expansion Port
Expansion PortExpansion Port
Expansion Port
MSA2000fc SAS (SFF8470) 4x lane 3 Gb SAS
MSA2300fc SAS (SFF8088) 4x lane 3 Gb SAS
QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
Technical Specifications
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 25