HP (Hewlett-Packard) 2500 Switch User Manual


 
6
reset the switch, in some cases the link will not complete; in other cases the link will complete but
at the former speed. For example, when changing from a 100 Mbps connection to a connection with
a 100/1000Base-T device, you may get a completed link, but it will be operating at the old speed
100 Mbps.
Manual Changes
To correct your switch Installation and Getting Started Guide (5969-2353) relative to the above
information, please keep the following information with the guide and note the pages where this
information applies:
Connecting to devices that have a fixed configuration:
Connecting with the fixed RJ-45 ports: The Series 2300 and 2500 fixed RJ-45 ports
have a default configuration of Auto. That is, when connecting to attached devices, the
switch will operate in one of two ways to determine the link speed and the communica-
tion mode (half duplex or full duplex):
if the connected device is also configured to Auto, the switch will automatically negotiate
link speed, communication mode, and flow control and a valid link should occur
if the connected device has a fixed configuration, for example 100 Mbps, at half or full
duplex, the switch will automatically sense the link speed, but will default to a communi-
cation of half duplex
Because the Series 2300 and 2500 switches behave in this way (in compliance with the IEEE
802.3 standard), if a device connected to the switchs fixed RJ-45 ports has a fixed
configuration at full duplex, a duplex mismatch occurs between the switch and the
connected device. The result will be high error rates and very inefficient communications
between the switch and the device.
Make sure that all devices connected to the fixed RJ-45 ports on the Series 2300 and 2500
switches are configured to auto negotiate, or are configured to connect at half duplex (all
hubs are configured this way, for example).
Connecting with the transceivers: The HP Procurve High-Speed Transceivers, when
installed in your Series 2300 and 2500 switches, are given a default configuration and
operate in specific ways as described below. Please read this information to determine
the effect of connecting the transceivers to devices with fixed configurations.
Page 3-2 change the bulleted item titled Connecting to devices that have a fixed full-duplex
configuration to the following:
Page 3-3 Add the information on page 2 and the top of page 3 of this Read Me First to the manual
before the bullet titled Check the port configuration (Series 2500 Switches only).
5968-2398-ed1a.fm Page 6 Tuesday, October 23, 2001 5:36 PM