Configuring HP ProLiant systems with Windows PE 12
if errorlevel 0 goto State0
:State0
REM *** Configure the target server hardware by reading the configuration
REM *** information in the script file
echo Running Configuration Replication Utility...
%Tools%\System\conrep -l -f%GlobalData%\HardwareSettings\hwconfig.xml -
x%Tools%\System\conrep.xml
echo Setting State Information...
%Tools%\System\statemgr /w Phase 1
:State1
REM========================================================================
REM *** Configure the array controllers by reading the configuration
REM *** information in the script file and stamping it onto the array
REM *** controllers of the target server
REM========================================================================
echo Configuring the Array Controllers...
%Tools%\System\ifhw .\hwdisc.xml %Tools%\System\allboards.xml PCI:"Smart
Array 5i Controller"
if errorlevel 1 GOTO NEXT1
%Tools%\ACU\bin\hpacubin.exe -i %GlobalData%\ArraySettings\pl-r0.ini
GOTO NEXT6
:NEXT1
%Tools%\System\ifhw .\hwdisc.xml %Tools%\System\allboards.xml PCI:"Smart
Array 6i Controller"
if errorlevel 1 GOTO NEXT2
%Tools%\ACU\bin\hpacubin.exe -i %GlobalData%\ArraySettings\pl-r1.ini
GOTO NEXT6
:NEXT2
%Tools%\System\ifhw .\hwdisc.xml %Tools%\System\allboards.xml PCI:"Smart
Array 5312"
if errorlevel 1 GOTO NEXT3
%Tools%\ACU\bin\hpacubin.exe -i %GlobalData%\ArraySettings\pl-r1.ini
GOTO NEXT6
:NEXT3
%Tools%\System\ifhw .\hwdisc.xml %Tools%\System\allboards.xml PCI:"Smart
Array 640X Controller"
if errorlevel 1 GOTO NEXT4
%Tools%\ACU\bin\hpacubin.exe -i %GlobalData%\ArraySettings\pl-r5.ini
GOTO NEXT6
:NEXT4
%Tools%\System\ifhw .\hwdisc.xml %Tools%\System\allboards.xml PCI:"Smart
Array P600 Controller"
if errorlevel 1 GOTO NEXT5
%Tools%\ACU\bin\hpacubin.exe -i %GlobalData%\ArraySettings\pl-r1r5.ini
GOTO NEXT6